Master clock D204SQ

Master clock D204SQ

D204SQ - small control panel of the exact time (master clock) for switching control, eventually also a slave clock. It has GPS input and COM232. It is used for switching ringtones in schools and managing secondary analogue and digital clocks in schools, offices, station buildings, etc.

    SLAVE IMPULSE LINE
    ADDITIONAL SYNCHRONIZATION
    For request
    Price on request
    Product number 10080000
    Request for price offer simply with green button "Request price". It works similar to cart, but It will create price request instead of order.

    BASIC TYPE DIVISION:

    Master clock D204 is available:
    • SQ (22W  power supply), PQ (63W power supply including 75VAC for older bell types)
    • Without slave link or with slave link
    • Input slot for GPS receiver and C232 interface to connect with PC.
    • Master clock with interface 485 could be synchronized from NTP using D213 converter
    NOTE: GPS slot could be used to connect GPS or DCF receiver.

    D201RQ/MAX CHARACTERISTICS:
    • master clock without slave link or with one slave link suitable for bell switching in small schools and for small time distribution systems (with slave link).
    • Passive energy backup - internal time of master clock is working during a power cut, but analog slave clocks are stopped. Analog slave clocks will be set up automatically after renewing the electricity supply
    • Metal wall-mounted casing.
    • Size 183x164x67 mm.
    • Input slot for GPS receiver. Should be connected to provide high accuracy. For example  GPS receiver D910SQ.
    • C232 interface to connect with PC. It is possible to use USB virtual COM converter.
    • Synchronization from link 485 could be added. It is bi-directional  interface. It is possible to use to set up slave clock with time from master clock or to set up master clock time from superior master clock device.
    • The master clock can be extended with a wireless DHF system with D216 converter.
    MINIMAL CONFIGURATION
    • Two relays programmable according to time. RELAY1 switch voltage 24VDC to output connector for bells. RELAY2 switches contact without voltage.
    • Input slot for GPS receiver. Should be connected to provide high accuracy. For example  GPS receiver D910SQ.
    • C232 interface to connect with PC. It is possible to use USB virtual COM converter. Remote control through LAN with MonTIME PC application (for windows).
    CONFIGURABLE OPTIONS

    SLAVE LINK:
    • NO - not installed
    • YES - One slave link is use to manage slave clocks (up to 20 pieces) . Could work in minute or second  mode.
    NOTE: Each slave polarized link is for voltage 24 VDC and has electronic current overload protection set to 0,25 A. Selection of minute/second mode with jumper  on link board.

    ADDITIONAL SYNCHRONIZATION:
    • NO - not used
    • C485 - It is possible to use to set up master clock time from superior master clock device or to synchronize slave clocks.
    • INPUT SLAVE LINK - to synchronize master clock time from superior SONTEK master clock




    TECHNICAL PARAMETERS:
    • Power supply standard: mains 230V / 50Hz
    • Power consumption: 22W
    • Protection: IP40
    • Dimensions: width 183mm, height: 164mm, thickness 67mm
    • Weight: 1 kg
    • Operating temperature: 0 to 40 ° C
    • Output capacity: 20 slave clocks (digital and analog)
    • Mounting: on the wall (pitch of mounting holes 165 mm)
    MOUNTING DIMENSIONS: